Oprava RAID v poli HP MSA2000

1) Clear meta data from LEFTOVER disks

  1. In the Configuration View panel, right-click the system and then select Tools > Clear Disk Metadata.

  2. In the main panel, select disks to clear metadata from.

  3. Click Clear Metadata. When processing is complete a success dialog appears.

  4. 4.  Click Ok


2) Re-Join Physical Disk to VDisk RAID

  1. In the HP MSA Storage Management Utility, Right click on the affected vdisk and select Configuration > Manage Dedicated Spares

  2. Your disk should appear in the list of available drives with a state of AVAIL. Tick the drive, then click the Modify Spares button.

  3. The disk will be re-joined to the array. Initially it may be listed as a spare, but the MSA will automatically re-join the disk as an active member of the RAID if this is how it was originally configured.

  4. The array will begin the Reconstruction process automatically. This can take a very long time depending on the size of your drives.

  5. In this situation, original SPARE has now become AVAIL. So, re-add this AVAIL disk as SPARE using above steps. After setting this as spare – this disk will now show a status of: VDISKSP or SPARE

napsáno 20.12.2017, před 1 měsícem

PF2018

Příjemné a pohodové prožití vánočních svátků.
napsáno 16.03.2017, před 10 měsíci

iNELS café káva jinak

Jak mít dům nebo kanceláře stále na dosah ruky.
napsáno 03.03.2017, před 11 měsíci

Nefunkční synchronizace na Exchange

Certifikáty StartCom a další již nejsou důvěryhodné.
napsáno 21.02.2017, před 11 měsíci

Co se stane s přístupem k mým datům když nezaplatím Office 365

Office 365 pro firmy: Životní cyklus předplatného.
napsáno 31.01.2017, před 12 měsíci

Změny v Office 365 pro rok 2017

Je potřeba sledovat i změny cloudových služeb Offoce 365.